Code – DTH50D
Description – Diathermy 50D
SURTRON® 50 D is a radiofrequency electrosurgical suitable for small monopoles surgery. SURTRON® 50 D through the functions selection makes possible pure cut, coagulation cut, and pure coagulation. The digital display of power erogation allows safety and very reproducible applications. SURTRON® 50 D permits use a professional surgery thanks to the stability functions and the safety system adopted. |
|
Main features | |
Maximum output power CUT (W) | 50 → 400 Ω |
Maximum output power CUT/COAG 1 (W) | 45 → 400 Ω |
Maximum output power CUT/COAG 2 (W) | 40 → 400 Ω |
Maximum output power COAG (W) | 40 → 400 Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115-230 |
Mains frequency Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 2,8 |
Size HxLxD mm | 180x100x180 |
Standard accessories | |
Unit eletricalsurgery code | 10100.05A |
Cable for rod neutral electrode | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Code – DTH80
Description – Diathermy 80W
SURTRON® is a radio surgical unit which is suitable to light and medium surgery. SURTRON®, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. It is continually monitored the connection of neutral electrode and, if a split neutral electrode is used, the neutral electrode to patient contact. The possibility to control the output functions, as well as the output power level, by the handle, allows implementing the surgical operation without turning away the surgeon attention from the surgical field. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 80 → 250Ω |
Maximum output power BLEND (W) | 60 → 200Ω |
Maximum output power FORCED COAG (W) | 50 → 150Ω |
Maximum output power SOFT COAG (W) | 40 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 30 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 7 |
Size HxLxD mm | 260x110x265 |
Standard accessories | |
Electrosurgical unit code | 10100.10A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code – DTH160
Description – Diathermy 160W
SURTRON® is a radio surgical unit which is suitable to light and medium surgery. SURTRON®, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. It is continually monitored the connection of neutral electrode and, if a split neutral electrode is used, the neutral electrode to patient contact. The possibility to control the output functions, as well as the output power level, by the handle, allows implementing the surgical operation without turning away the surgeon attention from the surgical field. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 160 → 250Ω |
Maximum output power BLEND (W) | 120 → 200Ω |
Maximum output power FORCED COAG (W) | 100 → 150Ω |
Maximum output power SOFT COAG (W) | 80 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 60 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 7 |
Size HxLxD mm | 260x110x265 |
Standard accessories | |
Electrosurgical unit code | 10100.30A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code – DTH120
Description – Diathermy 120W
SURTRON® is a radio surgical unit which is suitable to light and medium surgery. SURTRON®, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. It is continually monitored the connection of neutral electrode and, if a split neutral electrode is used, the neutral electrode to patient contact. The possibility to control the output functions, as well as the output power level, by the handle, allows implementing the surgical operation without turning away the surgeon attention from the surgical field. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 120 → 250Ω |
Maximum output power BLEND (W) | 90 → 200Ω |
Maximum output power FORCED COAG (W) | 80 → 150Ω |
Maximum output power SOFT COAG (W) | 60 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 40 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 7 |
Size HxLxD mm | 260x110x265 |
Standard accessories | |
Electrosurgical unit code | 10100.20A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code – DTH200
Description – Diathermy 200W
SURTRON® 200 is a proper diathermy-coagulator to monopoles or bipolar precise surgery. SURTRON® 200, allows to effect surgical minimally invasive treatment of resection, evaporation and coagulation. SURTRON® 200 through the selection of functions, it lets to effect pure (CUT), coagulated-CUT with different modulation duty-cycle (CUT90% – CUT80% – CUT70% – BLEND), surface coagulation (FORCED COAG), depth coagulation in absence of carbonization (SOFT COAG) and, with special adapter, bipolar cut (BIPOLAR CUT) and bipolar coagulation (BIPOLAR COAG). The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. SURTRON® 200 , by the ergonomic and safety solutions utilised, allows a highly professional surgery. It is continually monitored the connection of neutral electrode and, if a split neutral electrode is used, the impedance of the neutral electrode/patient contact is shown. The possibility to control by the handle the output functions, as well as the command of output power delivery, allows to implement the surgical operation without turning away the surgeon attention from the surgical field. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 200 → 250Ω |
Maximum output power CUT 90% (W) | 200 → 250Ω |
Maximum output power CUT 80% (W) | 200 → 250Ω |
Maximum output power CUT 70% (W) | 200 → 250Ω |
Maximum output power BLEND (W) | 120 → 200Ω |
Maximum output power FORCED COAG (W) | 150 → 150Ω |
Maximum output power SOFT COAG (W) | 90 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 120 → 250Ω |
Maximum output power BIPOLAR COAG(W) | 100 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 8 |
Size HxLxD mm | 360x150x265 |
Standard accessories | |
Electrosurgical unit code | 10100.40A |
Ball electrode Ø 4 mm length 6 cm | •/3 |
Bipolar selector | •/1 |
Blade electrode length 7 cm | •/3 |
Cable for neutral plate disposable/5365 | •/1 |
Disposable split neutral electrode | •/2 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needle electrode length 7 cm | •/3 |
Power supply cable 3×1.5mm SIE-IEC – 5mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode size 120×160 mm | •/1 |
Water-proof foot switch | •/1 |
Code – DTH80F
Description – Diathermy 80W Flash
SURTRON® FLASH is a diathermy-coagulator unit which is suitable to microsurgery as well as to precision monopoles and bipolar surgery SURTRON® FLASH, can supply RF operative powers either for programmable time as short as thousandths of a second or for the whole driving time carried out by a handpiece or a footswitch. SURTRON® FLASH, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® FLASH allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 80 → 250Ω |
Maximum output power BLEND (W) | 60 → 200Ω |
Maximum output power FORCED COAG (W) | 50 → 150Ω |
Maximum output power SOFT COAG (W) | 40 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 30 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 8 |
Size HxLxD mm | 360x150x265 |
Specifications | |
Electrosurgical unit code | 10300.05A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code – DTH120F
Description – Diathermy 120W Flash
SURTRON® FLASH is a diathermy-coagulator unit which is suitable to microsurgery as well as to precision monopoles and bipolar surgery. SURTRON® FLASH, can supply RF operative powers either for programmable time as short as thousandths of a second or for the whole driving time carried out by a hand piece or a footswitch. SURTRON® FLASH, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® FLASH allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 120 → 250Ω |
Maximum output power BLEND (W) | 90 → 200Ω |
Maximum output power FORCED COAG (W) | 80 → 150Ω |
Maximum output power SOFT COAG (W) | 60 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 40 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 8 |
Size HxLxD mm | 360x150x265 |
Specifications | |
Electrosurgical unit code | 10300.10A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code – DTH160F
Description – Diathermy 160W Flash
SURTRON® FLASH is a diathermy-coagulator unit which is suitable to microsurgery as well as to precision monopoles and bipolar surgery. SURTRON® FLASH, can supply RF operative powers either for programmable time as short as thousandths of a second or for the whole driving time carried out by a hand piece or a footswitch. SURTRON® FLASH, by means of the selections of the unit’s performance, allows pure cut CUT, coagulated cut BLEND, superficial coagulation COAG FORCED, deep coagulation, in absence of carbonization, COAG SOFT and, with a special adapter, bipolar coagulation BIPOLAR. The digital reading of the delivered power and the operative function’s monitoring by microcontroller guarantees the absolute reliability of working conditions. SURTRON® FLASH allows a highly professional surgery thanks to the ergonomic and safety solutions normally utilised. CONTROLS |
|
Main features | |
Maximum output power CUT (W) | 160 → 250Ω |
Maximum output power BLEND (W) | 120 → 200Ω |
Maximum output power FORCED COAG (W) | 100 → 150Ω |
Maximum output power SOFT COAG (W) | 80 → 100Ω |
Maximum output power BIPOLAR CUT(W) | 60 → 100Ω |
Working frequency | 600 kHz |
Mains voltage (Vac) | 115 –230 |
Mains frequency (Hz) | 50-60 |
Electrical class (EN60601-1) | I CF |
Neutral electrode | -F- |
Weight Kg | 8 |
Size HxLxD mm | 360x150x265 |
Specifications | |
Electrosurgical unit code | 10300.20A |
Cable for neutral plate disposable/5365 | •/1 |
Handle for microsurgical needle | •/1 |
Kit of assorted electrode length 5cm (10pcs) | •/1 |
Manual of instructions | •/1 |
Needles for micro-surgery length 1cm (5) | •/1 |
Not water-proof foot switch | •/1 |
Power supply cable 3x1mm SIE-IEC – 2mt | •/1 |
Reusable handle with finger switches | •/1 |
Steel neutral electrode | •/1 |
Code –
Description – Diathermy Electrosurgical Surtron 200W Flash
Code –
Description – Diathermy Electrosurgical Surtron 400 HP
TWIN OPERATIVE ACTIVITY – Two output channels for monopolar cutting - Two independent setting and output channels for the most frequent monopoloar coagulation CONTROLLED CUTTING PROCEDURES – Enhanced cutting current for scar free incision - Cutting current with selectable coagulating property for bleeding controlled dissection - Low capacitive coupling by Slow Blend current for endoscopic procedures TWIN CONTROLLED COAGULATIVE PROCEDURES – Speedy* coagulation and Deep** coagulation available to two operators - Spray coagulation available by hand switch or foot switch WIDE BIPOLAR FEATURES - Bipolar cutting current with selectable bleeding control - Slow Blend cutting current - Separately activable Automatic Start and Automatic Stop coagulation SURGEON AND PATIENT TOTAL SAFETY - Acceptability of contact impedance between patient body and return electrode continuously watched by Skin Plate Electronic Control (SPEC) - Excessive power delivery time warned - H.F. Leakage currents continuously monitored - Mains voltage variations automatically compensated before to start the delivery of HF power PERSONALIZED PROCEDURES - Independent choice of coagulate currents and power levels by each of two operators - Ten personal configurable and immediately recallable procedures EXTENSION DRIVER AND INTERLOCK SIGNALS - Drive output connection to external Argon-Plasma unit and Smoke Evacuator unit AUTOMATIC SELF DIAGNOSIS - Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories coded report of found failures * Speedy coagulation also said Fulgurate or Forced coagulation ** Deep Coagulation also said Pin Point, Desiccate or Soft coagulation |
Main features | |
Maximum output power monopolar pure CUT (W) | 400 → 300Ω |
Maximum output power monopolar cut-coag CUT80% (W) | 300→ 300Ω |
Maximum output power monopolar cut-coag CUT60% (W) | 250 → 300Ω |
Maximum output power monopolar cut-coag CUT40% (W) | 200 → 300Ω |
Maximum output power monopolar cut ENHANCED (W) | 250 → 300Ω |
Maximum output power monopolar cut-coag BLEND (W) | 250 → 500Ω |
Maximum output power monopolar coagulation SPEEDY (W) | 120 → 500Ω |
Maximum output power monopolar coagulation DEEP (W) | 120 → 200Ω |
Maximum output power monopolar spray-coagulation SPRAY (W) | 100 → 2000Ω |
Maximum output power monopolar spray-coagulation SPRAY ARGON (W) | 100 → 2000Ω |
Maximum output power bipolar CUT (W) | 120 → 150Ω |
Maximum output power bipolar cut-coag CUT 80% (W) | 100 → 150Ω |
Maximum output power bipolar cut-coag CUT 60% (W) | 100 → 150Ω |
Maximum output power bipolar cut-coag CUT 40% (W) | 60 → 150Ω |
Maximum output power bipolar cut-coag BLEND (W) | 100 → 300Ω |
Maximum output power bipolar coagulation COAG (W) | 70 → 100Ω |
Monopolar Working Frequency | 425kHz |
Bipolar Working Frequency | 525kHz |
Selectable power (Vac) | 115 – 230 |
Mains frequency (Hz) | 50- 60 |
Electrical class (EN60601 – 1) | I CF |
Neutral electrode | -F- |
Weight kg | 18 |
Size WxHxD mm | 470x150x380 |
Standard accessories | |
Unit electrosurgical unit code | 10400.90A |
Power supply cable 5MT 3 x 1.5mm SIEMENS-IEC | •/1 |
Cable for connection neutral plate | •/1 |
Blade electrode 7 cm | •/3 |
Blade electrode 15 cm | •/3 |
Ball electrode 7cm | •/3 |
Needle electrode 7cm | •/3 |
Disposable split neutral electrode | •/5 |
Disposable hand piece with finger switches | •/5 |
Reusable hand piece with finger switches | •/1 |
Instruction’s Manual | •/1 |
HP250-400 Double water-proof foot-switch | •/2 |
Electrode cleaning sponge | •/1 |
Accessories
Code – DTHBIFC5/115OBS
Description – Diathermy BIForceps Crv T0.5mm/S11.5cm
Code – DTHBIFC5/115OBS
Description – Diathermy BIForceps Crv T0.5mm/S11.5cm
Code – DTHBIFC1/17OBS
Description – Diathermy BIForceps Crv T1mm/S17cm
Code – DTHBIF2/195OBS
Description – Diathermy BIForceps T2mm/S19.5cm
Code – DTHBIFAC1/19OBS
Description – Diathermy BIForceps AngCrv T1mm/S19cm
Code – DTHBIFA2/20OBS
Description – Diathermy BIFprceps Ang T2mm/S20cm
Code – DTHB!-C3OBS
Description – Diathermy BI – Cable 3m
Code – DTHEB5/7OBS
Description – Diathermy Electrode – Ball 5mm-7cm
Code – DTHEBC3/7OBS
Description – Diathermy Electrode – Ball Crv 3mm-7cm
Code – DTHEBL7OBS
Description – Diathermy Electrode – Blade 7cm
Code – DTHEN7OBS
Description – Diathermy Electrode – Needle 7cm
Code – DTHENC7OBS
Description – Diathermy Electrode – Needle Crv 7cm
Code – DTHEL1/.5OBS
Description – Diathermy Electrode – Loop 1×0.5cm
Code – DTHEL1/1OBS
Description – Diathermy Electrode – Loop 1x1cm
Code – DTHES1/1OBS
Description – Diathermy Electrode – Square 1x1cm
Code – DTHET1.7/1.2OBS
Description – Diathermy Electrode – TriAnd 1.7×1.2cm
Code – DTHEPPDOBS
Description – Diathermy Electrode – Patient Plate Disp
Code – DTH-H/FSDOBS
Description – Diathermy – Handle & Finger Switch Disp
Code – DTH-H/FSOBS
Description – Diathermy – Handle & Finger Switch (ReUse)
Code – DTHM-PCONOBS
Description – Diathermy Mono – Plate Connector