Code – PM5100/NS
Description – P Monitor CMS5100 &NIBP/SPo2
Features | * Suitable for Adult, Pediatric and neonatal patient * 2.8”, High brightness TFT LCD display * High brightness LED display of NIBP, SPO2 and pulse rate * Memory: Built-in Flash Memory * Up to 2000 groups NIBP data storage and SPO2 data up to 48 hours. * Powerful data storage and management, Trend table * Visual and Audio alarms, adjustable * Audio volume adjustable * Built-in rechargeable Li-Polymer |
Specifications | |
Model | CMS5100 |
Display | 2.8” High Brightness TFT LCD display |
NIBP Method Mode Measurement Range Resolution Alarm |
Oscillometry Manual/Auto/Continuous 25 ~ 260mmHg 1mmHg; NIBP Accuracy: ±5mmHG SYS/DIA/MAP |
SP02 Measurement range Resolution Accuracy Alarm Range |
0%~100% 1% ±2% (70%-100%), 0% ~ 69% unspecified 0 ~100% |
Pulse Rate Measurement Range Resolution Accuracy |
10 ~ 270mmHg 1bpm ±2bpm or ±2% (select larger) |
Net Weight | 1.5kg |
Code –
Description – P Monitor CMS6000 & Pr/NIBP/SPo2/Tem/ECG
Code – PM6500/NSE
Description – P Monitor CMS6500 – NIBP/SPo2/ECG/Temp/Pulse 7” touch screen
Features | * 7” TFT Touch Screen, Led Backlight, 800 x 480 pixels * Visual and Audio Alarms, adjustable * Patient Management, Name and age and ID * Network with Central Station Software * Audio volume adjustable form 1 ~ 8 level * Multi-language options: Germany, France, Italian, Turkey, Etc. * Built-in removable and rechargeable lithium battery * UI with Both Keypad and the Touch Screen operation * Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive * Powerful data storage and management, Trend graph, Trend table, Etc. * Arrhythmia Analysis and S-T segment analysis |
Specifications | |
Model | CMS6500 |
ECG | Lead mode: 3-lead or 5-lead HR Range: 15 ~300 bpm Accuracy: ± 2bpm or ± 2%, which is greater |
NIBP | Method: Oscillometry Mode: Manual/Auto/Continuous Measurement Range: 25~260mmHg |
SPO2 | Measurement Range: 0 ~ 100% Accuracy: ±2% (70%~100%) 0% ~ 69% unspecified |
Pulse Rate | Measurement Range: 25 ~ 250bpm Accuracy: ± 3bpm |
Temperature | Standard with unit |
Dimensions | 191 x 160 x 244mm |
Net Weight | 2.1kg |
Code – PM6500-T
Description – P Monitor CMS6500 – Trolley
Code – PM6800/NSE
Description – P Monitor CMS6800 – NIBP/SPo2/ECG/Temp/Pulse 8” screen
Features | * 8” TFT, Led backlight, 800 x 480 pixels * Visual and Audio Alarms, adjustable * Patient Management, Name and age and ID * Network with Central Station Software * Audio volume adjustable form 1 ~ 8 level * Multi-language options: Germany, France, Italian, Turkey, Etc. * Built-in removable and rechargeable lithium battery * UI with Both Keypad and the Touch Screen operation * Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive * Powerful data storage and management, Trend graph, Trend table, Etc. * Arrhythmia Analysis and S-T segment analysis * Accuracy: ±2% (70% ~ 100%), 0% ~ 69% Unspecified |
Specifications | |
Model | CMS6800 |
ECG | Lead mode: 3-lead or 5-lead HR Range: 15 ~300 bpm Accuracy: ± 2bpm or ± 2%, which is greater |
NIBP | Method: Oscillometry Mode: Manual/Auto/Continuous Measurement Range: 25~260mmHg |
SPO2 | Measurement Range: 0 ~ 100% Accuracy: ±2% (70%~100%) 0% ~ 69% unspecified |
Pulse Rate | Measurement Range: 25 ~ 250bpm Accuracy: ± 3bpm |
Temperature | Standard with Unit |
Dimensions | 210 x 130 x 210mm |
Net Weight | 2.3kg |
Code – PM7000/PRNSTE
Description – P Monitor CMS7000 & Printer/NIBP/SPo2/Temp/ECG
Features | * 12.1″High brightness TFT LCD display * Portable ,streamline handle design * Big figure display * ECG Waveforms of 7-lead displayed in one screen * 96-hour tabular and graphic trends & date storage * Compatible and self-identify 3-lead and 5-lead ECG cable * NIBP dual Over Pressure Protection * Isolated floating, anti-defibrillation protected and anti-high-frequency interference |
Specifications | |
Model | CMS7000 |
Display | 12.1” high brightness TFT LCD display |
Nibp | |
Spo2 | |
Temperature | |
Heart rate & pulse rate | |
Respiration | |
ECG | 3/5 Lead |
Weight: | |
Power supply: |
Code – PM9000/NSE
Description – P Monitor CMS9000 & NIBP/SPo2/Temp/ECG
Features | 12.1” Screen, Colour TFT Screen, waveform up to 8 channels Light and portable with build-in rechargeable battery UP to 10 kinds of monitor parameters Arrhythmia analysis, pace-marker detection and S-T Segment analysis 72 hour storage and review of trend grams and tables, 40 second review of holographic waveform rms. Built-in recorder(option) All-round monitor of adult, paediatric and neonatal. Electrosurgical unit and defibrillation protected |
Specifications | |
Model | CMS9000 |
Display | Colour TFT Screen |
NIBP Method Operation Modes Measurement unit Measurement Types Measurement range Overpressure protection Resolution Accuracy Alarm |
Oscillometry Manual/Automatic/STAT mmGh/kPa selectable Systolic, Diastolic, Mean Adult 10 – 270mmHG YES 1mmHg Mean error and standard deviation per ANSI/AAMI SP-10 Systolic, Diastolic, Mean |
SP02 Measurement range Accuracy Alarm range |
0-100% ±2 digit (70~100%) 0 ~69% unspecified 0-100% |
ECG Input Lead Selection Gain selection Accuracy Protection Calibration Signal Operation modes Alarm Range Pediatric/Neonatal Alarm range S-T detection Alarm |
5-lead or 3-lead selectable 5-lead: RA, LA, RL, LL, V or R, L, N, F, C I, II, III, avr, avl, avf, vx, CAL 12.5mm/s, 25mm/s, 50mm/s ±1bpm or ±1%, whichever is greater Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation 1mV±5% Diagnostic, Monitor, Surgery 15-300bpm 15-350bpm -2.0mV~2.0mV Yes, Arrhythmia analysis: YES Yes, audible and visual alarm, alarm events recallable |
RESPIRATION Method Pediatric/Neonatal Alarm range Pediatric/Neonatal Apnea Alarm: |
RA-LL impedance 6-150rpm 6-120rpm 6-150rpm YES |
TEMPERATURE Resolution Channel Alarm range |
0.1°C Dual-channel 0-50°C |
Option: ETCO2 Measurement Mode Measurement range Accuracy Apnea alarm |
Side-stream or mainstream |
CO Method Measurement range |
Thermo-dilution CO: 0.1-20Lit./min |
IBP Channel Pressure transducer Transducer sites Alarm range |
2 channels Sensitivity: 5 (mV/V/mmHg) ART, PA, CVP, RAP, LAP, ICP -10~300mmHG |
Code – PM9200/PRNSTE
Description – P Monitor CMS9200 & Pr/NIBP/SPo2/Temp/ECG
Introduction | CMS9200 features in high cost-performance, high safety and low power consumption. To ensure monitoring quality and reduce operation risk, it adopts full-isolation(floating), ECG defibrillation-proof protection, ECG anti-high frequency surgical unit and NIBP dual-overpressure protection |
Features | Display mode: 15” color TFT LCD with high-resolution. Be applicable for adult, pediatric and neonatal for all-round monitoring. Operation interface with Chinese and English. Waveform and data can be set optionally. Storage of 72-hour trend data, and review of 40-second holographic waveform. Full-lead ECG display. 7-lead ECG displays in a screen, and ECG waveforms series display. Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads). Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability. Function of NIBP review, storage for up to 400 NIBP data. Network: connecting with central station, other Bed observation and software updating. Network connection mode: wireless and wired. Built-in rechargeable battery for uninterrupted monitoring. Standard parameters of ECG, RESP, NIBP, SpO2, TEMP and PR. Built-in printer(optional). Standard parameters of ECG, RESP, NIBP, SpO2, and TEMP. IBP, CO2 and thermal printer are optional |
Performance | ECG Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain ×0.25, ×0.5, ×1, ×2 HR Measuring and Alarm Range Range 15 ~ 300 bpm Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm ■ST Segment Monitoring Measuring and Alarm Range -0.6 mV~ + 0.8 mV ■ARR ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm Available Review Available Scan Speed for ECG Waveform 12.5mm/s, 25mm/s, 50mm/s ■Respiration (RESP) Method R-F(RA-LL) Impedance Measuring and Alarm Range for Resp. Rate: Adult 0~120rpm Pediatric and Neonatal 0~150rpm Resolution 1 rpm Measuring Accuracy 2 rpm Apnea Alarm 10 ~ 40 S ■SpO2 Measuring and Alarm Range 0 ~ 100 % Resolution 1 % Accuracy: 70% ~ 100% ±2% 0% ~ 69% unspecified ■PR Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm ■NIBP Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Resolution 1 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg ■TEMP Channel dual-channel Measuring and Alarm Range 0 ~ 50C Resolution 0.1C Accuracy ±0.1C Optional ■EtCO2 Method Side stream or Mainstream Measuring Range for CO2 0~150mmHg Resolution for CO2: 0.1 mm Hg 0 to 69 mm Hg 0.25 mm Hg 70 to 150 mm Hg Accuracy for CO2: 0 – 40 mm Hg ±2 mm Hg 41 – 70 mm Hg ±5% 71 – 100 mm Hg ±8% 101 – 150 mm Hg ±10% Respiration Rate>80BPM ±12% AwRR Range 2~150 rpm AwRR Accuracy ±1BPM Apnea Alarm Available ■IBP Channel dual-channel Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range -50~350 mm Hg Resolution 1 mm Hg Accuracy ±2% or 1mm Hg, which is greater ■Recorder Print Mode thermal array Recording Width 48mm Paper Speed 25mm/s, 50mm/s Quantity of Printing Waveform dual-channel ■Physical Characteristic: Dimension 365 x 150 x 340 (mm) Net Weight 4.0Kg |
Accessories | Adult SpO2 probe(5-pin) Adult NIBP cuff Extending tube for NIBP ECG lead ECG electrode Temperature probe IBP sensor(optional) IBP integration module(optional) IBP cable(optional) CO2 module(optional) CO2 collection pipe(optional) Power cord User Manual |
Code – PMS6
Description – P Monitor S6
Features | * 10.4” Colour TFT display, CRT or larger display can be connected simultaneously. * AC Power and internal rechargeable battery * 13 kinds of arrhythmia analysis, HRV and S-T segment analysis * 60 seconds ECG waveform review * 7-Channel ECG waveforms displayed simultaneously * Drug dose calculation * Maximum 72-hour graphic and tabular trends of all Parameters * Adjustable 3 level audio and visual alarm * Anti-high-frequency electrosurgical equipment * Optional with Built-in 3 channels thermal recorder. External Printer can be connected * Networked with central monitoring system by wired or wireless LAN * Applicable for Adult, Pediatric and Neonatal patient |
Specifications | |
Model | S6 |
Display | 10.4” Diagonal Screen 640 x 480 Pixel Colour TFT |
Displayed Parameters Time Alarms ECG Heart Rate NIBP Pulse Oximeter Respiration Rate Trends Temperatures Trace Freeze |
Battery-backed quartz crystal clock High & low limits selectable on patient parameters ECG Waveform Scale Derived from ECG or SPO2 Pressure (systolic, mean and diastolic) Pulse Rate, Pulse waveform and percent saturation Respiration rate derived from ECG HR, RR, NIBP, ST, TEMP, CO2 and SPO2 Two Channels Traces A & B |
ECG Display Gain Scales Sweep Speed Input Resistance Frequency Response CMRR Electrode Offset Potential Baseline Recovery Heart Rate Range Resolution Accuracy Alarm Lead off condition |
Standard Lead, I, II, III, aVL, aVR, aVF, Vx 2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s >5M Ohm (at 10Hz, not including patient cable) 0.05Hz – 100Hz (3dB) >80dB Maximum ±0.3V <5s after 5KV defibrillation 15bpm – 300bpm 1bpm <100bpm ±1% ≥100bpm ±2% Heart rate high and low limits alarm delay <12s Detected and displayed |
ST Segment range Accuracy |
-1.2mV to +1.2mV ±0.02mV |
SPO2 LED Specifications Alarm Display Display Update Resolution |
Range: 0% – 100% Accuracy: 80% – 100% ±2 digits, 70%-80% ±3digits, 0-69% unspecified Wavelength Radiant Power RED 660±2nm 1.8mW IR 905±10nm 2.0mW SPO2 high and low limits alarm delay <7s <5s 1% |
Pulse Rate: Measurement Range Resolution Accuracy Alarm delay |
20 to 250bpm 1bpm ±1bpm Pulse rate high and low limits alarm delay <7s |
NIBP Technique Patient Types Cuff Inflation Time Cuff inflation pressure Measurement Modes First Inflation Measurement |
Oscillometric method (with inflatable cuff) Determines systolic, diastolic and mean arterial pressures Adult, Pediatric and Neonatal 3-15s depending on cuff size Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure Manual: Immediate upon operator command AUTO: Determinations automatically made with selectable intervals STAT: Determinations continues in 5 minutes Adult/Pediatric/Neonatal |
Measurement Interval Time | 1 – 240min Step: 1 min (1min – 10min), 5min (10 min – 30min) 10 min (30min – 90min), 30min (90 – 240min) |
Measurement Range | Adult Systolic: 30mmHg – 225mmHg Diastolic:15mmHg – 220mm Hg Mean Arterial: 20mmHg~235mmHg |
Measurement Range | Infant Systolic: 30mmHg – 135mmHg Diastolic: 15mmHg – 110mmHg Mean Arterial: 20-125mmHg Pressure Resolution: 1mmHg |
Accuracy | Cuff Pressure Range: 0 to 275mmHg Pressure Span Accuracy: ±3mmHg Mean difference: ±5mmHg Standard deviation: 8mmHg |
Determination Time | Typically 25s. Varies with patient’s pulse rate, pulse pressure and amount of artifact present |
Overpressure Valve | Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg |
Overtime Protection | Stop determinates if the measurement time exceeds 120s/90s |
Alarm Delay | Pressure high and low limits alarm delay <7s |
RR Technique Range Resolution Accuracy Alarm delay |
Trans-thoracic impedance (RA-LL) 0-100 rpm 1 rpm ± 2 rpm (0-60rpm) Respiration rate high and low limits alarm delay <7s |
Temperature: Technique Channel Scales Probes Range Revolution Accuracy Alarm delay |
Resistance 2 (T1 and T2) F. or C. Resistive, recta and skin (reusable and disposable) YSI 400 Series types 0-50°C 0.1°C ±0.1°C Body temperature high and low limits alarm delay <7s |
CO2 (Optional) | |
IBP (Optional) | |
Power Requirements | 100-240VAC, 50/60Hz 1.6A max |
Internal Battery | 12V 7AH, typed-sealed lead-acid |
Operating Time | 2 hours typical at 25°C, no printing, one NIBP measurement |
(fully charged battery) | Per 15 min |
Alarm Range | Upper Range: HR 40-300pbm Systolic: (kpa)12-34 (mmHg) 90-255 Diastolic: (kpa) 8-29.3 (mmHg) 60-220 Mean Arterial (kPa) 4.6-29.3 (mmHg) 35-220 SPO2 (%) 80 – 100 RR (bpm) 10 – 120 Temp (°C) 25.5 – 45 (F°) 77.9 – 113 CO2 20-75mmHg PR (bpm) 30-300 Lower Range:20-160 Systolic: (kpa) 8-29.3 (mmHg) 60-220 Diagsolic: (kpa) 4-24 (mmHg) 30-180 Mean Arterial: (kPa) 4-26.6 (mmHg) 30-200 SPO2 (%) 70 – 99 RR (bpm) 5 – 80 Temp (°C) 25 – 44.5 (F°) 77 – 112.1 CO2 5-70 PR (bpm) 15-290 |
Code – PMSF
Description – P Monitor SF
Features | * 12.1” Colour TFT display, CRT or larger display can be connected simultaneously. * AC Power and internal rechargeable battery * 13 kinds of Arrhythmia analysis, HRV and S-T segment analysis * 60 seconds ECG waveform review * 7-Channel ECG waveforms displayed simultaneously * Drug dose calculation * Maximum 72-hour graphic and tabular trends of all Parameters * Adjustable 3 level audio and visual alarm * Anti-high-frequency electrosurgical equipment * Optional with Built-in 3 channels thermal recorder. * External Printer can be connected * Networked with central monitoring system by wired or wireless LAN * Applicable for Adult, Pediatric and Neonatal patient |
Specifications | |
Model | SF |
Display | 12.1 Inch Diagonal 800 x 600 Pixel Colour TFT |
Displayed Parameters: Time Alarms ECG Heart Rate NIBP Pulse Oximeter Respiration Rate Trends Temperatures Trace Freeze |
Battery-backed quartz crystal clock High & low limits selectable on patient parameters ECG Waveform Scale Derived from ECG or SPO2 Pressure (systolic, mean and diastolic) Pulse Rate, Pulse waveform and percent saturation Respiration rate derived from ECG HR, RR, NIBP, ST, TEMP, CO2 and SPO2 Two Channels Traces A & B |
ECG Display Gain Scales Sweep Speed Input Resistance Frequency Response CMRR Electrode Offset Potential Baseline Recovery Heart Rate Range Resolution Accuracy Alarm Lead off condition |
Protected against defibrillator and electro surgery potentials Standard Lead, I, II, III, aVL, aVR, aVF, Vx 2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s >5M Ohm (at 10Hz, not including patient cable) 0.05Hz – 100Hz (3dB) >80dB Maximum ±0.3V <5s after 5KV defibrillation 15bpm – 300bpm 1bpm <100bpm ±1% ≥100bpm ±2% Heart rate high and low limits alarm delay <12s Detected and displayed |
ST Segment range Accuracy |
-1.2mV to +1.2mV ±0.02mV |
SPO2 LED Specifications Alarm Display Display Update Resolution |
Range: 0% – 100% Accuracy: 80% – 100% ±2 digits, 70%-80% ±3digits, 0-69% unspecified Wavelength Radiant Power RED 660±2nm 1.8mW IR 905±10nm 2.0mW SPO2 high and low limits alarm delay <7s <5s 1% |
Pulse Rate: Measurement Range Resolution Accuracy Alarm delay |
20 to 250bpm 1bpm ±1bpm Pulse rate high and low limits alarm delay <7s |
NIBP Technique Patient Types Cuff Inflation Time Cuff inflation pressure Measurement Modes First Inflation Measurement |
Oscillometric method (with inflatable cuff) Determines systolic, diastolic and mean arterial pressures Adult, Pediatric and Neonatal 3-15s depending on cuff size Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure Manual: Immediate upon operator command AUTO: Determinations automatically made with selectable intervals STAT: Determinations continues in 5 minutes Adult/Pediatric/Neonatal |
Measurement Interval Time | 1 – 240min Step: 1 min (1min – 10min), 5min (10 min – 30min) 10 min (30min – 90min), 30min (90 – 240min) |
Measurement Range | Adult Systolic: 30mmHg – 225mmHg Diastolic:15mmHg – 220mm Hg Mean Arterial: 20mmHg~235mmHg |
Measurement Range | Infant Systolic: 30mmHg – 135mmHg Diastolic: 15mmHg – 110mmHg Mean Arterial: 20-125mmHg Pressure Resolution: 1mmHg |
Accuracy | Cuff Pressure Range: 0 to 275mmHg Pressure Span Accuracy: ±3mmHg Mean difference: ±5mmHg Standard deviation: 8mmHg |
Determination Time | Typically 25s. Varies with patient’s pulse rate, pulse pressure and amount of artifact present |
Overpressure Valve | Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg |
Overtime Protection | Stop determinates if the measurement time exceeds 120s/90s |
Alarm Delay | Pressure high and low limits alarm delay <7s |
RR Technique Range Resolution Accuracy Alarm delay |
Trans-thoracic impedance (RA-LL) 0-100 rpm 1 rpm ± 2 rpm (0-60rpm) Respiration rate high and low limits alarm delay <7s |
Temperature: Technique Channel Scales Probes Range Revolution Accuracy Alarm delay |
Resistance 2 (T1 and T2) F. or C. Resistive, recta and skin (reusable and disposable) YSI 400 Series types 0-50°C 0.1°C ±0.1°C Body temperature high and low limits alarm delay <7s |
CO2 (Optional) | |
IBP (Optional) | |
Power Requirements | 100-240VAC, 50/60Hz 1.6A max |
Internal Battery | 12V 7AH, typed-sealed lead-acid |
Operating Time | 2 hours typical at 25°C, no printing, one NIBP measurement |
(fully charged battery) | Per 15 min |
Alarm Range | Range: HR 40-300pbm Systolic: (kpa)12-34 (mmHg) 90-255 Diastolic: (kpa) 8-29.3 (mmHg) 60-220 Mean Arterial (kPa) 4.6-29.3 (mmHg) 35-220 SPO2 (%) 80 – 100 RR (bpm) 10 – 120 Temp (°C) 25.5 – 45 (F°) 77.9 – 113 CO2 20-75mmHg PR (bpm) 30-300 Lower Range:20-160 Systolic: (kpa) 8-29.3 (mmHg) 60-220 Diagsolic: (kpa) 4-24 (mmHg) 30-180 Mean Arterial: (kPa) 4-26.6 (mmHg) 30-200 SPO2 (%) 70 – 99 RR (bpm) 5 – 80 Temp (°C) 25 – 44.5 (F°) 77 – 112.1 CO2 5-70 PR (bpm) 15-290 |
Code – PMM3
Description – P Monitor M3
Features | * High-resolution 8.4” TFT display, with maximum 9 waveforms * 5 kinds of display mode, Large Font display mode * Parameters including: ECG, SPO2, NIBP, RESP, TEMP. HP & PR * ECG – 3 Lead * Built-in recorder and battery * Suitable for Adult, pediatric and neonatal patient * Net workable with our central monitoring system (Wired/Wireless) * 13 kinds of Arrhythmia analysis, S-T segment analysis * 72 hours data records, 100 items alarm event records * Adjustable 3-level audio and visual alarm |
Specifications | |
Model | M3 |
Display | LCD 5.7” color |
Dimensions | 258mm x 120mm x 243mm |
Weight | 3.5kg with 0.79kg battery 4.5kg with package |
ECG Display Gain Scales Sweep Speed Frequency Response Heart Rate Arrhythmia Analysis ST Segment |
7 lead: I, II, III, aVL, aVR, aVF, Vx 2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV 12.5mm/s, 25mm/s, 50mm/s three classes can be changed 0.05Hz – 100Hz (3dB) Range: 15bpm – 300bpm Accuracy: 100bpm ±1pm ≥ 100bpm ± 2% Analysis functions of 10 kinds of abnormal ECG waveforms. 32 times ECG data storing function and 4 seconds storing of every time Accuracy: error examination rate <20% Miss examination rate <20% Range: ±0.8mV Accuracy: <±0.05mV |
SPO2 | Range: 0% – 99% Accuracy: 70% – 79% ±2% 80% -99% ±3% |
NIBP | Technique: Oscillometric method Cuff Inflation Time:≤15s measuring time: ≤50s First Inflation Measurement: AUTO: 24kPa 180mmHg Manual: 9.3kPa (70mmHg), 13,3kPA (100mmHg) 16.0kPA (120mmHg), 18,6kPa (140mmHg), 20.0kPA (150mmHg), 21.3kPa (160mmHg), 24.0kPa (180mmHg) |
Measurement Interval Time | 1 min – 240min Step: 1 min (1min – 10min), 5min (10 min – 30min) 10 min (30min – 90min), 30min (90 – 240min) |
Measurement Range | Systolic: 4kPa (30mmHg – 225mmHg) Diastolic: 2kPa – 29.3kPa (10mmHg – 220mmHg) Mean Arterial: 2.7kPa ~31.3kPa (20mmHg~235mmHg) |
Measurement Accuracy | Static Pressure: ±3mmHg Pulse Rate: ±2% |
Response | Trans-thoracic impedance (RA-LL) Range: 2bpm~100bpm Accuracy: 15bpm~60bpm ≤2bpm 60bpm~100bpm ≤5bpm |
CO2 Method (additional option) | RR Range : 2bpm~60bpm (including Neonatal) RR Accuracy: ± 1bpm |
Temp | 2 (T1 and T2) channels Type: Rectal/Skin Range: 0°C~50°C Accuracy: during the 25°C~45°C, the measuring error ≤±0.2°C |
Waveform Display | Monitoring waveform ECG waveform: Scan Manner Trend Waveform Full-channel Range: 72 hours |
Alarm Range | Upper Range: HR 40-300pbm Systolic: (kpa)12-34 (mmHg) 90-255 Diastolic: (kpa) 8-29.3 (mmHg) 60-220 Mean Arterial (kPa) 4.6-29.3 (mmHg) 35-220 SPO2 (%) 80 – 100 RR (bpm) 10 – 120 Temp (°C) 25.5 – 45 (F°) 77.9 – 113 Difference In Temp (°C) 0.1 – 20 PR (bpm) 40-254 Lower Range:15-160 Systolic: (kpa) 8-29.3 (mmHg) 60-220 Diagsolic: (kpa) 4-24 (mmHg) 30-180 Mean Arterial: (kPa) 4-26.6 (mmHg) 30-200 SPO2 (%) 70 – 99 RR (bpm) 5 – 80 Temp (°C) 25 – 44.5 (F°) 77 – 112.1 Difference In Temp (°C) 0.1 – 36 PR (bpm) 20-160 |
Power Requirement | AC 100V-230V ±10%, 50Hz/60Hz |
Internal Battery: can work 1-2 hours continuously | |
Working Temperature | Temperature: 5°C-40°C Humidity: ≤80% (no condensation) |
Air Pressure: 86~106kPa |
Code – PMM3/PR
Description – P Monitor M3 & Printer
Code – PMBM3
Description – Vital signs monitor – Bionet – BM3 – ECG, SPo2, NIBP, Respiration and Temperature
Features | * Standard parameters: ECG, RESP, NIBP, SpO2, TEMP * 5.7” Colour LCD display * Standard Battery operation * Compatible with Nellcor reusable sensor * Disposable SPO2 sensor available * LAN Interface (central) optional * Trend printing |
Specifications | |
Model | BM3 |
Display | LCD 5.7” color |
Dimensions | 23.8cm x 25cm x 16.3cm |
Display Parameters | Up to 3 waves (ECG, SpO2, Respiration) Categorized alarms (3 priority levels) Visual Alarm Heart rate tone Battery status External power LED |
Interfaces | DC input connector: 11 to 16 VDC, 3A max Defib Sync Output Signal Level: 0 to 5V pulse Pulse Width: 100 ± 10ms LAN digital output for transferring data to an external computer |
Battery | Internal battery: sealed lead-acid Battery status indicator Operating Time: 2.5 hours typically |
Thermal Printer | Speeds:25, 50mm/sec Paper Width:58mm |
Tabular Trends | Memory Storage: 24 hours Date Interval:1, 5, 15, 30 min and 1 hour Tabular Format: One table for all variables |
Graphical Trends | Display Duration: 30, 60, 90 min. 3, 6 , 12 hours |
Operating Temperature | 0ºC to 50ºC |
Storage Temperature | -20ºC to 60ºC |
Power | DC 11 to 18VDC, 2.5 A max |
ECG | |
* Leads * Heart Rate Range * Bandwidth * Display sweep Speeds * ECG Size (sensitivity) * Pacemaker detection mode * Differential Input Impedance * CMRR * Input Dynamic Range * Defibrillator Discharge * Defib. Artifact recovery time * Arrhythmia analysis Lead off detection display |
3 Leads, 5 Leads (Optional) 30 to 300bpm 0.5Hz to 40Hz 25mm/sec 0.5, 1, 2, 4 mV/cm Indicator on waveform display, user selectable ≥ MΩ ≥ dB at 50 or 60 Hz ± 5mVAC, ± 300mVDC ≤5s ≤8s VTAC/VFIB VTAC ASYSTOLIC |
SPo2 | |
* % Saturation * Pulse Rate Range * SpO2 Accuracy * Pulse Rate accuracy |
0% to 100% 30 to 300bpm 70% to 100% ± 2 digits 0% to 69% unspecified ± 3 bpm |
NIBP | |
* Technique * Measurement Modes * Cuff Pressure Display * BP measurement Range * Pulse Rate Range * Adjustable Cuff Inflation Range |
Oscillometric Manual: Single measurement Auto: Automatic intervals of 1,2,3,4,5,10,15,20,30min 1,2,4,8 hours 30 to 300mmHg Systolic: 60 to 250mmHg Mean Arterial Pressure: 45 to 235mmHg Diastolic: 40 to 220mmHg 40 to 200bpm |
Respiration | |
* Range * Accuracy * Display Sweep Speeds |
5 to 120 breaths/min ± 3 breaths/min 25mm/sec |
Temperature unit | |
* Range * Accuracy |
15ºC to 45ºC 25ºC to 45ºC ± 0.1ºC 15ºC to 24ºC ± 0.2ºC |
Standard Accessories | 3-lead patient cable Disposable electrodes 10ea NIBP tubing (3m long) Reusable Adult cuff SpO2 sensor DC Adaptor (18 VDC, 2.5A) |
Optional Accessories | Temperature probe Surface skin Chart paper 5-lead patient cable |
Language Version | English, French, Spanish |
Code – PMBM3V
Description – Veterinary Monitor – Bionet – BM3 VET – ECG, SPo2, NIBP, Respiration and Temperature
Features | * Standard parameters: ECG, RESP, NIBP, SpO2, TEMP * 5.7” Colour LCD display * 58mm built-in printer * Direct keys for frequently used functions * Trim knob for easy menu setup * Convenient handle with hanger * Battery or Direct DC (18v) input for vehicle transport * Lightweight, easy to transport * Compact and rugged * Built-in 3 channel thermal printer * 24 hours of memory capacity * Free lifetime software upgrades |
Specifications | |
Model | BM3 – VET |
Display | LCD 5.7” color |
Dimensions | 23.8cm x 25cm x 16.3cm Approx. 3.5kg |
Display Parameters | Up to 3 waves (ECG, SpO2, Respiration) Categorized alarms (3 priority levels) Visual Alarm Heart rate tone Battery status External power LED |
Interfaces | DC input connector: 11 to 16 VDC, 3A max Defib Sync Output Signal Level: 0 to 5V pulse Pulse Width: 100 ± 10ms LAN digital output for transferring data to an external computer |
Battery | Internal battery: sealed lead-acid Battery status indicator Operating Time: 2.5 hours typically |
Thermal Printer | Speeds:25, 50mm/sec Paper Width:58mm |
Power Adapter | Adapter type (MW160KA1803F01) Input: 100 – 240 vac (50/60Hz) Output: 18Vdc, 2.5A |
Tabular Trends | Memory Storage: 24 hours Date Interval:1, 5, 15, 30 min and 1 hour Tabular Format: One table for all variables |
Graphical Trends | Display Duration: 30, 60, 90 min. 3, 6 , 12 hours |
Standard Accessory | 3-lead ECG cable – 1ea |
Accessory | Electrodes – 10ea NIBP tubing, 3m long – 1ea Blood pressure cuff (reusable) – 1ea Sp02 sensor extension cable (2m) – 1ea Sp02 sensor (Y type) – 1ea DC adapter, 18VDC, 2.5A – 1ea |
Optional Accessory | Temperature probe, reusable (OPTION) Thermal paper (OPTION) |
ECG | |
* Leads * Heart Rate Range * Heart Rate Accuracy * Bandwidth * Display sweep Speeds * ECG Size (sensitivity) * Pacemaker detection mode * Differential Input Impedance * CMRR * Input Dynamic Range * Defibrillator Discharge * Defib. Artifact recovery time |
3 Leads 30 to 300bpm +/- 3bpm 0.5Hz to 40Hz 25mm/sec 0.5, 1, 2, 4 mV/cm Indicator on waveform display, user selectable ≥ 5MΩ ≥ 90dB at 50 or 60 Hz ± 5mVAC, ± 300mVDC ≤5s ≤8s |
SPo2 | |
* % Saturation * Pulse Rate Range * SpO2 Accuracy * Pulse Rate accuracy |
0% to 100% 30 to 300bpm 70% to 100% ± 2 digits 0% to 69% unspecified ± 3 bpm |
NIBP | |
* Technique * Measurement Modes * * Cuff Pressure Display * BP measurement Range * Adjustable Cuff Inflation Range |
Oscillometric Manual: Single measurement Auto: Automatic intervals of 1,2,3,4,5,10,15,20,30min 1,2,4,8 hours 30 to 300mmHg Systolic: 60 to 250mmHg Mean Arterial Pressure: 45 to 235mmHg Diastolic: 40 to 220mmHg |
Respiration | |
Range Accuracy Display Sweep Speeds |
50to 120 breaths/min ± 3 breaths/min 25mm/sec |
Temperature unit | |
Range Accuracy |
15ºC to 45ºC 25ºC to 45ºC ± 0.1ºC 15ºC to 24ºC ± 0.2ºC |
Compatible with | YS1 Series 400 temperature probes |
Code – PMBM5
Description – Vital signs monitor – Bionet – BM5 – ECG, SPo2, NIBP, IBP Respiration and Temperature
Code – PMBM5-ETC02
Description – P Monitor BM5 – ETC02 Module
Code – TRO
Description – Trolley for patient monitor – Please enquire – price depends on model required
Hand held patient monitors
Code – PM50
Description – P Monitors PM50 hand held NIBP/SPo2
Features | * Compact and portable, easy to use * Suitable for adult, pediatric and neonatal patient. * Large color LCD display of NIBP, SpO2 and Pulse rate * Adjustable audible and visual alarms * Real-time ambulatory monitoring. 24 hours storage and review of date. * All date can be transferred to a PC through Windows-based software For review and print |
SPo2 | |
Measurement Range: 35-100% Resolution: 1% Accuracy: 70-100% ± 2% 0-69% unspecified Alarm range: 0-100% |
|
Pulse rate | |
Range: 0-254bpm Resolution: 1bpm Accuracy: ± 1bpm Alarm range: 0-254bpm |
|
Specifications | |
Display: Color LCD Power: Two “AA”, 1.5V Alkali Battery Dimension: 120x80x32mm Weight: <350g(Including Batteries) |
|
NIBP | |
Method: Oscillometry Mode: Manual/Automatic/continuous Measurement Range: 25-260mmHg(Max: 280mmHg) Automatic Measurement Interval: 5, 10, 15, 30, 45, 60, 90 minutes Resolution: ImmHg Overpressure Protection: 300mmHg Alarm: Systolic, Diastolic, mean Alarm range: 10-270mmHg |
Code – PM70
Description – P Monitor PM70 – NIBP SPo2 pulse, internal battery backup
Features | * Routine Check Mode and Continuous Monitoring Mode * Data Graph and Trend Table Review * Rich Analysis Report * Sync with PC based Software (WinXP and Win Vista) * lightweight and easy-to-use portable unit * Built-in NIBP module * Automated & on-demand NIBP measurements * User or system-defined inflation pressure * ECG is optional |
NIBP | * Performance Specifications * Display:3.5″ Color TFT * Resolution:320×240 * Display Mode: Standard face, Waveform face * Indicator: Power indicator light, Alarm sound, Pulse tone * Interface: socket for connecting sensors and sockets for communication cables * Power Supply: DC 5V, <300mA * Battery: Built-in Li-Polymer, 2 hours for charging, 3 hours for continuous working.8 hours for standby mode * Trend Graph: Resolution from 1s, 5s, 10s. Maximum time 96 hours. * Trend Table: Resolution from 1s, 5s, 10s. Review up to 1000 items. * Alarm: Adjustable High and Low limits. Three level audible and visual alarm * User Configuration: All the color of parameters and waves can be set according to user’s willing |
Technical specifications | * Safety * Meet the requirment of IEC60601 series * Type of Protection:Class II with internal electirc power supply * Degree of Protection:BF * Dimention and Weight * Dimention:145(W)x95(H)x37(D)mm * Weight:400g(with battery) * Operation Environment: * Temperature:0℃~ +40℃ * Humidity:15% ~ 95% * Storage Environment: * Temperature:-20℃~ +60℃ * Humidity:10% ~ 95% * Patient Range * Neonate ,Pediatric and Adult |
SPo2 | * Measurement Range:0 ~ 100% Resolution:1%* Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion) ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified* Alarm Range:0% ~ 100%* Refreshing Rate:1s |
Pulse rate | * Measurement Range:25 ~ 250 bpm * Resolution:1bpm * Accuracy:±3 bpm (non-motion) * Alarm Range:25 ~ 250 bmp * Refreshing Rate:1s |
NIBP | * Method:Oscillometry * Mode:Manual/Auto/Contiuous * Measurement Range:25 ~ 260mmHg * Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes * Resolution:1mmHg * Overpressure Protection: 300mmHg * Alarm range: 25 ~260mmHg |
Cuffs and Accessories for Patient Monitors – contec
Code – PM5000-CUFA
Description – Cuff Adult
Code – PM5000-CUFO
Description – Cuff Obese
Code – PM5000-CUFFP
Description – Cuff Paediatric
Code – PM5000-CUFC
Description – Cuff Child
Code – PM5000-CUFNN
Description – Cuff Neonate
Code – PM5000-YP
Description – Y Probe