Patient Monitors

Code – PM5100/NS
Description – P Monitor CMS5100 &NIBP/SPo2
 PM5100NS

Features * Suitable for Adult, Pediatric and neonatal patient
* 2.8”, High brightness TFT LCD display
* High brightness LED display of NIBP, SPO2 and pulse rate
* Memory: Built-in Flash Memory
* Up to 2000 groups NIBP data storage and SPO2 data up to 48 hours.
* Powerful data storage and management, Trend table
* Visual and Audio alarms, adjustable
* Audio volume adjustable
* Built-in rechargeable Li-Polymer
 
Specifications
Model CMS5100
Display 2.8” High Brightness TFT LCD display
NIBP
Method
Mode
Measurement Range
Resolution
Alarm
Oscillometry
Manual/Auto/Continuous
25 ~ 260mmHg
1mmHg; NIBP Accuracy: ±5mmHG
SYS/DIA/MAP
SP02
Measurement range
Resolution
Accuracy
Alarm Range
0%~100%
1%
±2% (70%-100%), 0% ~ 69% unspecified
0 ~100%
Pulse Rate
Measurement Range
Resolution
Accuracy
10 ~ 270mmHg
1bpm
±2bpm or ±2% (select larger)
Net Weight 1.5kg

 


Code –
Description – P Monitor CMS6000 & Pr/NIBP/SPo2/Tem/ECG


Code – PM6500/NSE
Description – P Monitor CMS6500 – NIBP/SPo2/ECG/Temp/Pulse 7” touch screen
  PM6500NSE

Features * 7” TFT Touch Screen, Led Backlight, 800 x 480 pixels
* Visual and Audio Alarms, adjustable
* Patient Management, Name and age and ID
* Network with Central Station Software
* Audio volume adjustable form 1 ~ 8 level
* Multi-language options: Germany, France, Italian, Turkey, Etc.
* Built-in removable and rechargeable lithium battery
* UI with Both Keypad and the Touch Screen operation
* Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive
* Powerful data storage and management, Trend graph, Trend table, Etc.
* Arrhythmia Analysis and S-T segment analysis
   
Specifications  
Model CMS6500
ECG Lead mode: 3-lead or 5-lead
HR Range: 15 ~300 bpm
Accuracy: ± 2bpm or ± 2%, which is greater
NIBP Method: Oscillometry
Mode: Manual/Auto/Continuous
Measurement Range: 25~260mmHg
SPO2 Measurement Range: 0 ~ 100%
Accuracy: ±2% (70%~100%)
0% ~ 69% unspecified
Pulse Rate Measurement Range: 25 ~ 250bpm
Accuracy: ± 3bpm
Temperature Standard with unit
Dimensions 191 x 160 x 244mm
Net Weight 2.1kg

 


Code – PM6500-T
Description – P Monitor CMS6500 – Trolley
  PM6500-T


Code – PM6800/NSE
Description – P Monitor CMS6800 – NIBP/SPo2/ECG/Temp/Pulse 8” screen
  PM6800NSE

Features * 8” TFT, Led backlight, 800 x 480 pixels
* Visual and Audio Alarms, adjustable
* Patient Management, Name and age and ID
* Network with Central Station Software
* Audio volume adjustable form 1 ~ 8 level
* Multi-language options: Germany, France, Italian, Turkey, Etc.
* Built-in removable and rechargeable lithium battery
* UI with Both Keypad and the Touch Screen operation
* Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive
* Powerful data storage and management, Trend graph, Trend table, Etc.
* Arrhythmia Analysis and S-T segment analysis
* Accuracy: ±2% (70% ~ 100%), 0% ~ 69% Unspecified
   
Specifications  
Model CMS6800
ECG Lead mode: 3-lead or 5-lead
HR Range: 15 ~300 bpm
Accuracy: ± 2bpm or ± 2%, which is greater
NIBP Method: Oscillometry
Mode: Manual/Auto/Continuous
Measurement Range: 25~260mmHg
SPO2 Measurement Range: 0 ~ 100%
Accuracy: ±2% (70%~100%)
0% ~ 69% unspecified
Pulse Rate Measurement Range: 25 ~ 250bpm
Accuracy: ± 3bpm
Temperature Standard with Unit
Dimensions 210 x 130 x 210mm
Net Weight 2.3kg

  


Code – PM7000/PRNSTE
Description – P Monitor CMS7000 & Printer/NIBP/SPo2/Temp/ECG
  PM7000PRNSTE

Features * 12.1″High brightness TFT LCD display
* Portable ,streamline handle design
* Big figure display
* ECG Waveforms of 7-lead displayed in one screen
* 96-hour tabular and graphic trends & date storage
* Compatible and self-identify 3-lead and 5-lead ECG cable
* NIBP dual Over Pressure Protection
* Isolated floating, anti-defibrillation protected and anti-high-frequency interference
   
Specifications  
Model CMS7000
Display 12.1” high brightness TFT LCD display
Nibp  
Spo2  
Temperature  
Heart rate & pulse rate  
Respiration  
ECG 3/5 Lead
Weight:  
Power supply:  

  


Code – PM9000/NSE
Description – P Monitor CMS9000 & NIBP/SPo2/Temp/ECG
  PM9000NSE

Features 12.1” Screen, Colour TFT Screen, waveform up to 8 channels
Light and portable with build-in rechargeable battery
UP to 10 kinds of monitor parameters
Arrhythmia analysis, pace-marker detection and S-T Segment analysis
72 hour storage and review of trend grams and tables, 40 second review of holographic waveform rms.
Built-in recorder(option)
All-round monitor of adult, paediatric and neonatal.
Electrosurgical unit and defibrillation protected
   
Specifications  
Model CMS9000
Display Colour TFT Screen
NIBP
Method
Operation Modes
Measurement unit
Measurement Types
Measurement range
Overpressure protection
Resolution
Accuracy
Alarm
 
Oscillometry
Manual/Automatic/STAT
mmGh/kPa selectable
Systolic, Diastolic, Mean
Adult 10 – 270mmHG
YES
1mmHg
Mean error and standard deviation per ANSI/AAMI SP-10
Systolic, Diastolic, Mean
SP02
Measurement range
Accuracy
Alarm range
 
0-100%
±2 digit (70~100%) 0 ~69% unspecified
0-100%
ECG
Input
Lead Selection
Gain selection
Accuracy
Protection
 
Calibration Signal
Operation modes
Alarm Range
Pediatric/Neonatal
Alarm range
S-T detection
Alarm
5-lead or 3-lead selectable
5-lead: RA, LA, RL, LL, V or R, L, N, F, C
I, II, III, avr, avl, avf, vx, CAL
12.5mm/s, 25mm/s, 50mm/s
±1bpm or ±1%, whichever is greater
Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
1mV±5%
Diagnostic, Monitor, Surgery
15-300bpm
15-350bpm
-2.0mV~2.0mV
Yes, Arrhythmia analysis: YES
Yes, audible and visual alarm, alarm events recallable
RESPIRATION
Method
Pediatric/Neonatal
Alarm range
Pediatric/Neonatal
Apnea Alarm:
 
RA-LL impedance
6-150rpm
6-120rpm
6-150rpm
YES
TEMPERATURE
Resolution
Channel
Alarm range
0.1°C
Dual-channel
0-50°C
Option:
ETCO2
Measurement Mode
Measurement range
Accuracy
Apnea alarm

Side-stream or mainstream
EtC02: 0-99mmHg
CO2 concentration
YES

CO
Method
Measurement range
Thermo-dilution
CO: 0.1-20Lit./min
IBP
Channel
Pressure transducer
Transducer sites
Alarm range
2 channels
Sensitivity: 5 (mV/V/mmHg)
ART, PA, CVP, RAP, LAP, ICP
-10~300mmHG

 


Code – PM9200/PRNSTE
Description – P Monitor CMS9200 & Pr/NIBP/SPo2/Temp/ECG
  PM9200PRNSTE

Introduction CMS9200 features in high cost-performance, high safety and low power consumption. To ensure monitoring quality and reduce operation risk, it adopts full-isolation(floating), ECG defibrillation-proof protection, ECG anti-high frequency surgical unit and NIBP dual-overpressure protection
Features Display mode: 15” color TFT LCD with high-resolution.
Be applicable for adult, pediatric and neonatal for all-round monitoring.
Operation interface with Chinese and English.
Waveform and data can be set optionally.
Storage of 72-hour trend data, and review of 40-second holographic waveform.
Full-lead ECG display.
7-lead ECG displays in a screen, and ECG waveforms series display.
Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
Function of NIBP review, storage for up to 400 NIBP data.
Network: connecting with central station, other Bed observation and software updating.
Network connection mode: wireless and wired.
Built-in rechargeable battery for uninterrupted monitoring.
Standard parameters of ECG, RESP, NIBP, SpO2, TEMP and PR.
Built-in printer(optional).
Standard parameters of ECG, RESP, NIBP, SpO2, and TEMP.
IBP, CO2 and thermal printer are optional
Performance ECG
Lead Mode 3-lead and 5-lead are optional
Lead Selection I, II, III, avR, avL, avF, V
Wave 5-lead: 2 channels
3-lead: 1channel
Gain ×0.25, ×0.5, ×1, ×2
HR Measuring and Alarm Range
Range 15 ~ 300 bpm
Accuracy ±1% or ±1bpm, which is greater
Alarm Accuracy ±2bpm
Resolution 1 bpm
■ST Segment Monitoring
Measuring and Alarm Range -0.6 mV~ + 0.8 mV
■ARR
ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available
Scan Speed for ECG Waveform 12.5mm/s, 25mm/s, 50mm/s
■Respiration (RESP)
Method R-F(RA-LL) Impedance
Measuring and Alarm Range for Resp. Rate:
Adult 0~120rpm
Pediatric and Neonatal 0~150rpm
Resolution 1 rpm
Measuring Accuracy 2 rpm
Apnea Alarm 10 ~ 40 S
SpO2
Measuring and Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy:
70% ~ 100% ±2%
0% ~ 69% unspecified
■PR
Measuring and Alarm Range 0~250bpm
Resolution 1bpm
Measuring Accuracy ±2bpm or ±2%, which is greater
Alarm Accuracy ±2bpm
NIBP
Method Oscillometry
Mode Manual, Auto, continuous
Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90 Min
Measuring Period in Continuous Mode 5 Min
Measuring and Alarm Range 10~270mmHg
Resolution 1 mmHg
Accuracy ±10% or ±8mmHg, which is greater
Over-pressure Protection:
Adult Mode 315±10 mmHg
Pediatric Mode 265±10 mmHg
Neonatal Mode 155±10 mmHg
TEMP
Channel dual-channel
Measuring and Alarm Range 0 ~ 50C
Resolution 0.1C
Accuracy ±0.1C
Optional
EtCO2
Method Side stream or Mainstream Measuring Range for CO2 0~150mmHg
Resolution for CO2:
0.1 mm Hg 0 to 69 mm Hg
0.25 mm Hg 70 to 150 mm Hg
Accuracy for CO2:
0 – 40 mm Hg ±2 mm Hg
41 – 70 mm Hg ±5%
71 – 100 mm Hg ±8%
101 – 150 mm Hg ±10%
Respiration Rate>80BPM ±12%
AwRR Range 2~150 rpm
AwRR Accuracy ±1BPM
Apnea Alarm Available
IBP
Channel dual-channel
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range -50~350 mm Hg
Resolution 1 mm Hg
Accuracy ±2% or 1mm Hg, which is greater
Recorder
 Print Mode thermal array
Recording Width 48mm
Paper Speed 25mm/s, 50mm/s
Quantity of Printing Waveform dual-channel
Physical Characteristic:
Dimension 365 x 150 x 340 (mm)
Net Weight 4.0Kg
Accessories Adult SpO2 probe(5-pin)
Adult NIBP cuff
Extending tube for NIBP
ECG lead
ECG electrode
Temperature probe
IBP sensor(optional)
IBP integration module(optional)
IBP cable(optional)
CO2 module(optional)
CO2 collection pipe(optional)
Power cord
User Manual

 


Code – PMS6
Description – P Monitor S6
  PMS6

Features * 10.4” Colour TFT display, CRT or larger display can be connected simultaneously.
* AC Power and internal rechargeable battery
* 13 kinds of arrhythmia analysis, HRV and S-T segment analysis
* 60 seconds ECG waveform review
* 7-Channel ECG waveforms displayed simultaneously
* Drug dose calculation
* Maximum 72-hour graphic and tabular trends of all Parameters
* Adjustable 3 level audio and visual alarm
* Anti-high-frequency electrosurgical equipment
* Optional with Built-in 3 channels thermal recorder. External Printer can be connected
* Networked with central monitoring system by wired or wireless LAN
* Applicable for Adult, Pediatric and Neonatal patient
   
Specifications  
Model S6
Display 10.4” Diagonal Screen
640 x 480 Pixel Colour TFT
Displayed Parameters
Time
Alarms
ECG
Heart Rate
NIBP
Pulse Oximeter
Respiration Rate
Trends
Temperatures
Trace Freeze
 
Battery-backed quartz crystal clock
High & low limits selectable on patient parameters
ECG Waveform Scale
Derived from ECG or SPO2
Pressure (systolic, mean and diastolic)
Pulse Rate, Pulse waveform and percent saturation
Respiration rate derived from ECG
HR, RR, NIBP, ST, TEMP, CO2 and SPO2
Two Channels
Traces A & B
ECG
Display Gain Scales
 
Sweep Speed
Input Resistance
Frequency Response
CMRR
Electrode Offset Potential
Baseline Recovery
Heart Rate Range
Resolution
Accuracy
Alarm
Lead off condition
Standard Lead, I, II, III, aVL, aVR, aVF, Vx
2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV
6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
>5M Ohm (at 10Hz, not including patient cable)
0.05Hz – 100Hz (3dB)
>80dB
Maximum ±0.3V
<5s after 5KV defibrillation
15bpm – 300bpm
1bpm
<100bpm ±1% ≥100bpm ±2%
Heart rate high and low limits alarm delay <12s
Detected and displayed
ST Segment range
Accuracy
-1.2mV to +1.2mV
±0.02mV
SPO2
 
 
LED Specifications
 
 
Alarm Display
Display Update
Resolution
Range: 0% – 100%
Accuracy: 80% – 100% ±2 digits, 70%-80% ±3digits, 0-69% unspecified
Wavelength  Radiant Power
RED 660±2nm 1.8mW
IR 905±10nm 2.0mW
SPO2 high and low limits alarm delay <7s
<5s
1%
Pulse Rate:
Measurement Range
Resolution
Accuracy
Alarm delay
20 to 250bpm
1bpm
±1bpm
Pulse rate high and low limits alarm delay <7s
NIBP
Technique
 
Patient Types
Cuff Inflation Time
Cuff inflation pressure
 
Measurement Modes
 
 
 
First Inflation Measurement
Oscillometric method (with inflatable cuff)
Determines systolic, diastolic and mean arterial pressures
Adult, Pediatric and Neonatal
3-15s depending on cuff size
Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure
Manual: Immediate upon operator command
AUTO: Determinations automatically made with selectable intervals
STAT: Determinations continues in 5 minutes
Adult/Pediatric/Neonatal
Measurement Interval Time 1 – 240min
Step: 1 min (1min – 10min), 5min (10 min – 30min)
10 min (30min – 90min), 30min (90 – 240min)
Measurement Range Adult
Systolic: 30mmHg – 225mmHg
Diastolic:15mmHg – 220mm Hg
Mean Arterial: 20mmHg~235mmHg
Measurement Range Infant
Systolic: 30mmHg – 135mmHg
Diastolic: 15mmHg – 110mmHg
Mean Arterial: 20-125mmHg
Pressure Resolution: 1mmHg
Accuracy Cuff Pressure Range: 0 to 275mmHg
Pressure Span Accuracy: ±3mmHg
Mean difference: ±5mmHg
Standard deviation: 8mmHg
Determination Time Typically 25s. Varies with patient’s pulse rate, pulse pressure and amount of artifact present
Overpressure Valve Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg
Overtime Protection Stop determinates if the measurement time exceeds 120s/90s
Alarm Delay Pressure high and low limits alarm delay <7s
RR
Technique
Range
Resolution
Accuracy
Alarm delay
Trans-thoracic impedance (RA-LL)
0-100 rpm
1 rpm
± 2 rpm (0-60rpm)
Respiration rate high and low limits alarm delay <7s
Temperature:
Technique
Channel
Scales
Probes

Range

Revolution
Accuracy
Alarm delay
Resistance
2 (T1 and T2)
F. or C.
Resistive, recta and skin (reusable and disposable)
YSI 400 Series types
0-50°C
0.1°C
±0.1°C
Body temperature high and low limits alarm delay <7s
CO2 (Optional)
IBP (Optional)
Power Requirements 100-240VAC, 50/60Hz 1.6A max
Internal Battery 12V 7AH, typed-sealed lead-acid
Operating Time 2 hours typical at 25°C, no printing, one NIBP measurement
(fully charged battery) Per 15 min
Alarm Range Upper Range: HR 40-300pbm
Systolic: (kpa)12-34
(mmHg) 90-255
Diastolic: (kpa) 8-29.3
(mmHg) 60-220
Mean Arterial (kPa) 4.6-29.3
(mmHg) 35-220
SPO2 (%) 80 – 100
RR (bpm) 10 – 120
Temp (°C) 25.5 – 45
(F°) 77.9 – 113
CO2 20-75mmHg
PR (bpm) 30-300
Lower Range:20-160
Systolic: (kpa) 8-29.3
(mmHg) 60-220
Diagsolic: (kpa) 4-24
(mmHg) 30-180
Mean Arterial: (kPa) 4-26.6
(mmHg) 30-200
SPO2 (%) 70 – 99
RR (bpm) 5 – 80
Temp (°C) 25 – 44.5
(F°) 77 – 112.1
CO2 5-70
PR (bpm) 15-290

 


Code – PMSF
Description – P Monitor SF
  PMSF

Features * 12.1” Colour TFT display, CRT or larger display can be connected simultaneously.
* AC Power and internal rechargeable battery
* 13 kinds of Arrhythmia analysis, HRV and S-T segment analysis
* 60 seconds ECG waveform review
* 7-Channel ECG waveforms displayed simultaneously
* Drug dose calculation
* Maximum 72-hour graphic and tabular trends of all Parameters
* Adjustable 3 level audio and visual alarm
* Anti-high-frequency electrosurgical equipment
* Optional with Built-in 3 channels thermal recorder.
* External Printer can be connected
* Networked with central monitoring system by wired or wireless LAN
* Applicable for Adult, Pediatric and Neonatal patient
   
Specifications  
Model SF
Display 12.1 Inch Diagonal
800 x 600 Pixel Colour TFT
Displayed Parameters:
Time
Alarms
ECG
Heart Rate
NIBP
Pulse Oximeter
Respiration Rate
Trends
Temperatures
Trace Freeze
 
Battery-backed quartz crystal clock
High & low limits selectable on patient parameters
ECG Waveform Scale
Derived from ECG or SPO2
Pressure (systolic, mean and diastolic)
Pulse Rate, Pulse waveform and percent saturation
Respiration rate derived from ECG
HR, RR, NIBP, ST, TEMP, CO2 and SPO2
Two Channels
Traces A & B
ECG
 
Display Gain Scales
 
Sweep Speed
Input Resistance
Frequency Response
CMRR
Electrode Offset Potential
Baseline Recovery
Heart Rate Range
Resolution
Accuracy
Alarm
Lead off condition
Protected against defibrillator and electro surgery potentials
Standard Lead, I, II, III, aVL, aVR, aVF, Vx
2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV
6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
>5M Ohm (at 10Hz, not including patient cable)
0.05Hz – 100Hz (3dB)
>80dB
Maximum ±0.3V
<5s after 5KV defibrillation
15bpm – 300bpm
1bpm
<100bpm ±1% ≥100bpm ±2%
Heart rate high and low limits alarm delay <12s
Detected and displayed
ST Segment range
Accuracy
-1.2mV to +1.2mV
±0.02mV
SPO2
 
 
LED Specifications
 
 
Alarm Display
Display Update
Resolution
Range: 0% – 100%
Accuracy: 80% – 100% ±2 digits, 70%-80% ±3digits, 0-69% unspecified
Wavelength  Radiant Power
RED 660±2nm 1.8mW
IR 905±10nm 2.0mW
SPO2 high and low limits alarm delay <7s
<5s
1%
Pulse Rate:
Measurement Range
Resolution
Accuracy
Alarm delay
20 to 250bpm
1bpm
±1bpm
Pulse rate high and low limits alarm delay <7s
NIBP
Technique
 
Patient Types
Cuff Inflation Time
Cuff inflation pressure
 
Measurement Modes
 
 
 
First Inflation Measurement
Oscillometric method (with inflatable cuff)
Determines systolic, diastolic and mean arterial pressures
Adult, Pediatric and Neonatal
3-15s depending on cuff size
Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure
Manual: Immediate upon operator command
AUTO: Determinations automatically made with selectable intervals
STAT: Determinations continues in 5 minutes
Adult/Pediatric/Neonatal
Measurement Interval Time 1 – 240min
Step: 1 min (1min – 10min), 5min (10 min – 30min)
10 min (30min – 90min), 30min (90 – 240min)
Measurement Range Adult
Systolic: 30mmHg – 225mmHg
Diastolic:15mmHg – 220mm Hg
Mean Arterial: 20mmHg~235mmHg
Measurement Range Infant
Systolic: 30mmHg – 135mmHg
Diastolic: 15mmHg – 110mmHg
Mean Arterial: 20-125mmHg
Pressure Resolution: 1mmHg
Accuracy Cuff Pressure Range: 0 to 275mmHg
Pressure Span Accuracy: ±3mmHg
Mean difference: ±5mmHg
Standard deviation: 8mmHg
Determination Time Typically 25s. Varies with patient’s pulse rate, pulse pressure and amount of artifact present
Overpressure Valve Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg
Overtime Protection Stop determinates if the measurement time exceeds 120s/90s
Alarm Delay Pressure high and low limits alarm delay <7s
RR
Technique
Range
Resolution
Accuracy
Alarm delay
Trans-thoracic impedance (RA-LL)
0-100 rpm
1 rpm
± 2 rpm (0-60rpm)
Respiration rate high and low limits alarm delay <7s
Temperature:
Technique
Channel
Scales
Probes

Range

Revolution
Accuracy
Alarm delay
Resistance
2 (T1 and T2)
F. or C.
Resistive, recta and skin (reusable and disposable)
YSI 400 Series types
0-50°C
0.1°C
±0.1°C
Body temperature high and low limits alarm delay <7s
CO2 (Optional)  
IBP (Optional)  
Power Requirements 100-240VAC, 50/60Hz 1.6A max
Internal Battery 12V 7AH, typed-sealed lead-acid
Operating Time 2 hours typical at 25°C, no printing, one NIBP measurement
(fully charged battery) Per 15 min
Alarm Range Range: HR 40-300pbm
Systolic: (kpa)12-34
(mmHg) 90-255
Diastolic: (kpa) 8-29.3
(mmHg) 60-220
Mean Arterial (kPa) 4.6-29.3
(mmHg) 35-220
SPO2 (%) 80 – 100
RR (bpm) 10 – 120
Temp (°C) 25.5 – 45
(F°) 77.9 – 113
CO2 20-75mmHg
PR (bpm) 30-300
Lower Range:20-160
Systolic: (kpa) 8-29.3
(mmHg) 60-220
Diagsolic: (kpa) 4-24
(mmHg) 30-180
Mean Arterial: (kPa) 4-26.6
(mmHg) 30-200
SPO2 (%) 70 – 99
RR (bpm) 5 – 80
Temp (°C) 25 – 44.5
(F°) 77 – 112.1
CO2 5-70
PR (bpm) 15-290

 


Code – PMM3
Description – P Monitor M3
  PMM3

Features * High-resolution 8.4” TFT display, with maximum 9 waveforms
* 5 kinds of display mode, Large Font display mode
* Parameters including: ECG, SPO2, NIBP, RESP, TEMP. HP & PR
* ECG – 3 Lead
* Built-in recorder and battery
* Suitable for Adult, pediatric and neonatal patient
* Net workable with our central monitoring system (Wired/Wireless)
* 13 kinds of Arrhythmia analysis, S-T segment analysis
* 72 hours data records, 100 items alarm event records
* Adjustable 3-level audio and visual alarm
   
Specifications  
Model M3
Display LCD 5.7” color
Dimensions 258mm x 120mm x 243mm
Weight 3.5kg with 0.79kg battery
4.5kg with package
ECG
Display Gain Scales
 
Sweep Speed
Frequency Response
Heart Rate
 
 
Arrhythmia Analysis
 
 
 
 
ST Segment
7 lead: I, II, III, aVL, aVR, aVF, Vx
2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV
12.5mm/s, 25mm/s, 50mm/s three classes can be changed
0.05Hz – 100Hz (3dB)
Range: 15bpm – 300bpm
Accuracy: 100bpm ±1pm
≥ 100bpm ± 2%
Analysis functions of 10 kinds of abnormal ECG waveforms.
32 times ECG data storing function and 4 seconds storing of every time
Accuracy: error examination rate <20%
Miss examination rate <20%
Range: ±0.8mV
Accuracy: <±0.05mV
SPO2 Range: 0% – 99%
Accuracy: 70% – 79% ±2%
80% -99% ±3%
NIBP Technique: Oscillometric method
Cuff Inflation Time:≤15s measuring time: ≤50s
First Inflation Measurement: AUTO: 24kPa 180mmHg
Manual: 9.3kPa (70mmHg), 13,3kPA (100mmHg)
16.0kPA (120mmHg), 18,6kPa (140mmHg), 20.0kPA
(150mmHg), 21.3kPa (160mmHg), 24.0kPa
(180mmHg)
Measurement Interval Time 1 min – 240min
Step: 1 min (1min – 10min), 5min (10 min – 30min)
10 min (30min – 90min), 30min (90 – 240min)
Measurement Range Systolic: 4kPa (30mmHg – 225mmHg)
Diastolic: 2kPa – 29.3kPa (10mmHg – 220mmHg)
Mean Arterial: 2.7kPa ~31.3kPa (20mmHg~235mmHg)
Measurement Accuracy Static Pressure: ±3mmHg
Pulse Rate: ±2%
Response Trans-thoracic impedance (RA-LL)
Range: 2bpm~100bpm
Accuracy: 15bpm~60bpm ≤2bpm
60bpm~100bpm ≤5bpm
CO2 Method (additional option) RR Range : 2bpm~60bpm (including Neonatal)
RR Accuracy: ± 1bpm
Temp 2 (T1 and T2) channels
Type: Rectal/Skin
Range: 0°C~50°C
Accuracy: during the 25°C~45°C, the measuring error ≤±0.2°C
Waveform Display Monitoring waveform
ECG waveform: Scan Manner
Trend Waveform
Full-channel
Range: 72 hours
Alarm Range Upper Range: HR 40-300pbm
Systolic: (kpa)12-34
(mmHg) 90-255
Diastolic: (kpa) 8-29.3
(mmHg) 60-220
Mean Arterial (kPa) 4.6-29.3
(mmHg) 35-220
SPO2 (%) 80 – 100
RR (bpm) 10 – 120
Temp (°C) 25.5 – 45
(F°) 77.9 – 113
Difference
In Temp (°C) 0.1 – 20
PR (bpm) 40-254
Lower Range:15-160
Systolic: (kpa) 8-29.3
(mmHg) 60-220
Diagsolic: (kpa) 4-24
(mmHg) 30-180
Mean Arterial: (kPa) 4-26.6
(mmHg) 30-200
SPO2 (%) 70 – 99
RR (bpm) 5 – 80
Temp (°C) 25 – 44.5
(F°) 77 – 112.1
Difference
In Temp (°C) 0.1 – 36
PR (bpm) 20-160
Power Requirement AC 100V-230V ±10%, 50Hz/60Hz
  Internal Battery: can work 1-2 hours continuously
Working Temperature Temperature: 5°C-40°C
Humidity: ≤80% (no condensation)
  Air Pressure: 86~106kPa

  


Code – PMM3/PR
Description – P Monitor M3 & Printer


Code – PMBM3
Description – Vital signs monitor – Bionet – BM3 – ECG, SPo2, NIBP, Respiration and Temperature
  PMBM3

Features * Standard parameters: ECG, RESP, NIBP, SpO2, TEMP
* 5.7” Colour LCD display
* Standard Battery operation
* Compatible with Nellcor reusable sensor
* Disposable SPO2 sensor available
* LAN Interface (central) optional
* Trend printing
   
Specifications  
Model BM3
Display LCD 5.7” color
Dimensions 23.8cm x 25cm x 16.3cm
Display Parameters Up to 3 waves (ECG, SpO2, Respiration)
Categorized alarms (3 priority levels)
Visual Alarm
Heart rate tone
Battery status
External power LED
Interfaces DC input connector: 11 to 16 VDC, 3A max
Defib Sync Output
Signal Level: 0 to 5V pulse
Pulse Width: 100 ± 10ms
LAN digital output for transferring data to an external computer
Battery Internal battery: sealed lead-acid
Battery status indicator
Operating Time: 2.5 hours typically
Thermal Printer Speeds:25, 50mm/sec
Paper Width:58mm
Tabular Trends Memory Storage: 24 hours
Date Interval:1, 5, 15, 30 min and 1 hour
Tabular Format: One table for all variables
Graphical Trends Display Duration: 30, 60, 90 min. 3, 6 , 12 hours
Operating Temperature 0ºC to 50ºC
Storage Temperature -20ºC to 60ºC
Power DC 11 to 18VDC, 2.5 A max
ECG  
Leads
Heart Rate Range
Bandwidth
Display sweep Speeds
ECG Size (sensitivity)
Pacemaker detection mode
Differential Input Impedance
CMRR
Input Dynamic Range
Defibrillator Discharge
Defib. Artifact recovery time
Arrhythmia analysis
 
Lead off detection display
3 Leads, 5 Leads (Optional)
30 to 300bpm
0.5Hz to 40Hz
25mm/sec
0.5, 1, 2, 4 mV/cm
Indicator on waveform display, user selectable
≥ MΩ
≥ dB at 50 or 60 Hz
± 5mVAC, ± 300mVDC
≤5s
≤8s
VTAC/VFIB
VTAC
ASYSTOLIC
SPo2  
% Saturation
Pulse Rate Range
SpO2 Accuracy
 
Pulse Rate accuracy
0% to 100%
30 to 300bpm
70% to 100% ± 2 digits
0% to 69% unspecified
± 3 bpm
NIBP  
Technique
Measurement Modes
 
 
Cuff Pressure Display
BP measurement Range
 
 
Pulse Rate Range
Adjustable Cuff Inflation Range
Oscillometric
Manual: Single measurement
Auto: Automatic intervals of 1,2,3,4,5,10,15,20,30min
1,2,4,8 hours
30 to 300mmHg
Systolic: 60 to 250mmHg
Mean Arterial Pressure: 45 to 235mmHg
Diastolic: 40 to 220mmHg
40 to 200bpm
Respiration  
Range
Accuracy
Display Sweep Speeds
5 to 120 breaths/min
± 3 breaths/min
25mm/sec
Temperature unit  
Range
Accuracy
15ºC to 45ºC
25ºC to 45ºC ± 0.1ºC
15ºC to 24ºC ± 0.2ºC
Standard Accessories 3-lead patient cable
Disposable electrodes 10ea
NIBP tubing (3m long)
Reusable Adult cuff
SpO2 sensor
DC Adaptor (18 VDC, 2.5A)
Optional Accessories Temperature probe Surface skin
Chart paper
5-lead patient cable
Language Version English, French, Spanish

 


Code – PMBM3V
Description – Veterinary Monitor – Bionet – BM3 VET – ECG, SPo2, NIBP, Respiration and Temperature
  PMBM3V

Features * Standard parameters: ECG, RESP, NIBP, SpO2, TEMP
* 5.7” Colour LCD display
* 58mm built-in printer
* Direct keys for frequently used functions
* Trim knob for easy menu setup
* Convenient handle with hanger
* Battery or Direct DC (18v) input for vehicle transport
* Lightweight, easy to transport
* Compact and rugged
* Built-in 3 channel thermal printer
* 24 hours of memory capacity
* Free lifetime software upgrades
   
Specifications  
Model BM3 – VET
Display LCD 5.7” color
Dimensions 23.8cm x 25cm x 16.3cm
Approx. 3.5kg
Display Parameters Up to 3 waves (ECG, SpO2, Respiration)
Categorized alarms (3 priority levels)
Visual Alarm
Heart rate tone
Battery status
External power LED
Interfaces DC input connector: 11 to 16 VDC, 3A max
Defib Sync Output
Signal Level: 0 to 5V pulse
Pulse Width: 100 ± 10ms
LAN digital output for transferring data to an external computer
Battery Internal battery: sealed lead-acid
Battery status indicator
Operating Time: 2.5 hours typically
Thermal Printer Speeds:25, 50mm/sec
Paper Width:58mm
Power Adapter Adapter type (MW160KA1803F01)
Input: 100 – 240 vac (50/60Hz)
Output: 18Vdc, 2.5A
Tabular Trends Memory Storage: 24 hours
Date Interval:1, 5, 15, 30 min and 1 hour
Tabular Format: One table for all variables
Graphical Trends Display Duration: 30, 60, 90 min. 3, 6 , 12 hours
Standard Accessory 3-lead ECG cable – 1ea
Accessory Electrodes – 10ea
NIBP tubing, 3m long – 1ea
Blood pressure cuff (reusable) – 1ea
Sp02 sensor extension cable (2m) – 1ea
Sp02 sensor (Y type) – 1ea
DC adapter, 18VDC, 2.5A – 1ea
Optional Accessory Temperature probe, reusable (OPTION)
Thermal paper (OPTION)
ECG  
Leads
Heart Rate Range
Heart Rate Accuracy
Bandwidth
Display sweep Speeds
ECG Size (sensitivity)
Pacemaker detection mode
Differential Input Impedance
CMRR
Input Dynamic Range
Defibrillator Discharge
Defib. Artifact recovery time
3 Leads
30 to 300bpm
+/- 3bpm
0.5Hz to 40Hz
25mm/sec
0.5, 1, 2, 4 mV/cm
Indicator on waveform display, user selectable
≥ 5MΩ
≥ 90dB at 50 or 60 Hz
± 5mVAC, ± 300mVDC
≤5s
≤8s
SPo2
% Saturation
Pulse Rate Range
SpO2 Accuracy
 
Pulse Rate accuracy
0% to 100%
30 to 300bpm
70% to 100% ± 2 digits
0% to 69% unspecified
± 3 bpm
NIBP
Technique
Measurement Modes
 
 
 
Cuff Pressure Display
BP measurement Range
 
 
Adjustable Cuff Inflation Range
Oscillometric
Manual: Single measurement
Auto: Automatic intervals of 1,2,3,4,5,10,15,20,30min
1,2,4,8 hours
30 to 300mmHg
Systolic: 60 to 250mmHg
Mean Arterial Pressure: 45 to 235mmHg
Diastolic: 40 to 220mmHg
Respiration
Range
Accuracy
Display Sweep Speeds
50to 120 breaths/min
± 3 breaths/min
25mm/sec
Temperature unit
Range
Accuracy
15ºC to 45ºC
25ºC to 45ºC ± 0.1ºC
15ºC to 24ºC ± 0.2ºC
Compatible with YS1 Series 400 temperature probes

 


Code – PMBM5
Description – Vital signs monitor – Bionet – BM5 – ECG, SPo2, NIBP, IBP Respiration and Temperature
 


Code – PMBM5-ETC02
Description – P Monitor BM5 – ETC02 Module


Code – TRO
Description – Trolley for patient monitor – Please enquire – price depends on model required
 TRO


Hand held patient monitors


Code – PM50
Description – P Monitors PM50 hand held NIBP/SPo2
  PM50

Features * Compact and portable, easy to use
* Suitable for adult, pediatric and neonatal patient.
* Large color LCD display of NIBP, SpO2 and Pulse rate
* Adjustable audible and visual alarms
* Real-time ambulatory monitoring. 24 hours storage and review of date.
* All date can be transferred to a PC through Windows-based software For review and print
SPo2  
  Measurement Range: 35-100%
Resolution: 1%
Accuracy: 70-100% ± 2% 0-69% unspecified
Alarm range: 0-100%
Pulse rate  
  Range: 0-254bpm
Resolution: 1bpm
Accuracy: ± 1bpm
Alarm range: 0-254bpm
   
Specifications  
  Display: Color LCD
Power: Two “AA”, 1.5V Alkali Battery
Dimension: 120x80x32mm
Weight: <350g(Including Batteries)
NIBP
  Method: Oscillometry
Mode: Manual/Automatic/continuous
Measurement Range: 25-260mmHg(Max: 280mmHg)
Automatic Measurement Interval: 5, 10, 15, 30, 45, 60, 90 minutes
Resolution: ImmHg
Overpressure Protection: 300mmHg
Alarm: Systolic, Diastolic, mean Alarm range: 10-270mmHg

 


Code – PM70
Description – P Monitor PM70 – NIBP SPo2 pulse, internal battery backup
  PM70

Features * Routine Check Mode and Continuous Monitoring Mode
* Data Graph and Trend Table Review
* Rich Analysis Report
* Sync with PC based Software (WinXP and Win Vista)
* lightweight and easy-to-use portable unit
* Built-in NIBP module
* Automated & on-demand NIBP measurements
* User or system-defined inflation pressure
* ECG is optional
NIBP * Performance Specifications
* Display:3.5″ Color TFT
* Resolution:320×240
* Display Mode: Standard face, Waveform face
* Indicator: Power indicator light, Alarm sound, Pulse tone
* Interface: socket for connecting sensors and sockets for communication cables
* Power Supply: DC 5V, <300mA
* Battery: Built-in Li-Polymer, 2 hours for charging, 3 hours
for continuous working.8 hours for standby mode
* Trend Graph: Resolution from 1s, 5s, 10s. Maximum time 96 hours.
* Trend Table: Resolution from 1s, 5s, 10s. Review up to 1000 items.
* Alarm: Adjustable High and Low limits. Three level audible and visual alarm
* User Configuration: All the color of parameters and waves can be set according to user’s willing
Technical specifications * Safety
* Meet the requirment of IEC60601 series
* Type of Protection:Class II with internal electirc power supply
* Degree of Protection:BF
* Dimention and Weight
* Dimention:145(W)x95(H)x37(D)mm
* Weight:400g(with battery)
* Operation Environment:
* Temperature:0℃~ +40℃
* Humidity:15% ~ 95%
* Storage Environment:
* Temperature:-20℃~ +60℃
* Humidity:10% ~ 95%
* Patient Range
* Neonate ,Pediatric and Adult
SPo2 * Measurement Range:0 ~ 100%
Resolution:1%* Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified* Alarm Range:0% ~ 100%* Refreshing Rate:1s
Pulse rate * Measurement Range:25 ~ 250 bpm
* Resolution:1bpm
* Accuracy:±3 bpm (non-motion)
* Alarm Range:25 ~ 250 bmp
* Refreshing Rate:1s
NIBP * Method:Oscillometry
* Mode:Manual/Auto/Contiuous
* Measurement Range:25 ~ 260mmHg
* Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes
* Resolution:1mmHg
* Overpressure Protection: 300mmHg
* Alarm range: 25 ~260mmHg

 


Cuffs and Accessories for Patient Monitors – contec


Code – PM5000-CUFA
Description – Cuff Adult


Code – PM5000-CUFO
Description – Cuff Obese


Code – PM5000-CUFFP
Description – Cuff Paediatric


Code – PM5000-CUFC
Description – Cuff Child


Code – PM5000-CUFNN
Description – Cuff Neonate


Code – PM5000-YP
Description – Y Probe